Hanna-instruments HI 4009 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Hanna-instruments HI 4009. Hanna Instruments HI 4009 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
HI 4009HI 4009
HI 4009HI 4009
HI 4009
HI 4109HI 4109
HI 4109HI 4109
HI 4109
Cyanide Ion
Selective Electrode
Instruction Manual
Half-cell
Combination
CYANIDE
HI 4009
HI 4109
CYANIDE
COMBINATION
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Combination

1HI 4009HI 4009HI 4009HI 4009HI 4009HI 4109HI 4109HI 4109HI 4109HI 4109Cyanide IonSelective ElectrodeInstruction Manual Half-cell CombinationCYA

Strona 2

10IX. IX. IX. IX. IX. Quick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode Slo

Strona 3

11 • If the membrane is damaged, the response becomesextremely sluggish, or the slope of the electrode hasdecreased significantly, and procedures abo

Strona 4

12 Procedure1) Follow sections VIII and IX to prepare sensors formeasurement.2) Follow section VI to prepare standards / solution.Standards

Strona 5

13XII. XII. XII. XII. XII. Other Measurement TOther Measurement TOther Measurement TOther Measurement TOther Measurement Techniquesechniquesechniquese

Strona 6

14A cyanide electrode may be used as an indicator to followthe progress and detect the endpoint of a complexationtitration of CN- with silver nitrate

Strona 7

15sensor membrane. Store dry disassembled electrode instorage box provided with electrode.XVXVXVXVXV. . . . . Conversion TConversion TConversion

Strona 8 - Deionized

16MAN4109 03/09R2 WARRANTY WARRANTY WARRANTY WARRANTY WARRANTYHanna Instruments Ion Selective Electrodes are warran

Strona 9 - COMBINATION

2HI 4009 Cyanide Half-cellHI 4009 Cyanide Half-cellHI 4009 Cyanide Half-cellHI 4009 Cyanide Half-cellHI 4009 Cyanide Half-cellHI 4109 Cyanide Combinat

Strona 10 - and place against damaged

3III. III. III. III. III. Theory of OperationTheory of OperationTheory of OperationTheory of OperationTheory of Operation:::::The HI 4009 or HI 4109 C

Strona 11

4IV. IV. IV. IV. IV. Design elements of the HI 4009 and HI 4109Design elements of the HI 4009 and HI 4109Design elements of the HI 4009 and HI 41

Strona 12

5V. V. V. V. V. Equipment required:Equipment required:Equipment required:Equipment required:Equipment required:• Hanna HI 5315 Double Junction Re

Strona 13

6capped plastic bottle. Using volumetric pipettes and glass-ware make dilutions to bracket the concentration of thesamples. Store standards in plasti

Strona 14

7 HI 4000-70.• Avoid large changes in temperature (thermal shock)as it may damage the sensor.• Gas bubbles may form from solution out-gass

Strona 15

8VIII. VIII. VIII. VIII. VIII. Electrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationHI 4

Strona 16 - MAN4109 03/09R2

96. Holding the body of the electrode gently press uppercap with your thumb. This permits the fill solution todrain out of the body. Release cap and

Powiązane modele: HI 4109