Hanna-instruments HI 4012 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Hanna-instruments HI 4012. Hanna Instruments HI 4012 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
HI 4012HI 4012
HI 4012HI 4012
HI 4012
HI 4112HI 4112
HI 4112HI 4112
HI 4112
Lead Ion
Selective Electrode
Instruction Manual
Half-cell
Combination
LEAD/SULFATE
HI 4012
HI 4112
LEAD/SULFATE
COMBINATION
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Combination

1HI 4012HI 4012HI 4012HI 4012HI 4012HI 4112HI 4112HI 4112HI 4112HI 4112Lead IonSelective ElectrodeInstruction Manual Half-cell CombinationLEAD/S

Strona 2 - +2 +2

10IX. IX. IX. IX. IX. Quick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode Slo

Strona 3 - . Lead sensors are “elec

11 applying gentle pressure. Continue polishing untilyou are satisfied with the surface. If dark depositsappear on polishing strip move the p

Strona 4 - LEAD/SULFATE

12 Procedure1) Follow sections VIII and IX to prepare sensors formeasurement.2) Follow section VI to prepare standards / solution.Standards

Strona 5

13This technique is called Known Addition. The method canuse an ideal sensor slope, but actual determined slopes atthe temperature of measurement sh

Strona 6

14the sulfate ions forming a precipitate.Pb2+ + SO4.2- <—> PbSO4 (insoluble)At the stoichiometric end point, a change in mV occurs.Measuremen

Strona 7

15Plot generated on Hanna HI 901 Titrator duringPlot generated on Hanna HI 901 Titrator duringPlot generated on Hanna HI 901 Titrator duringPlot ge

Strona 8 - Deionized

16MAN4112 01/07 WARRANTY WARRANTY WARRANTY WARRANTY WARRANTYHanna Instruments Ion Selective Electrodes are warrante

Strona 9 - COMBINATION

2HI 4012 Lead Half-cellHI 4012 Lead Half-cellHI 4012 Lead Half-cellHI 4012 Lead Half-cellHI 4012 Lead Half-cellHI 4112 Lead Combination Electrod

Strona 10

3III. III. III. III. III. Theory of OperationTheory of OperationTheory of OperationTheory of OperationTheory of Operation:::::The HI 4012 or HI 4112 l

Strona 11

4IV. IV. IV. IV. IV. Design elements of the HI 4012 and HI 4112Design elements of the HI 4012 and HI 4112Design elements of the HI 4012 and HI 41

Strona 12

5V. V. V. V. V. Equipment required:Equipment required:Equipment required:Equipment required:Equipment required:• Hanna HI 5315 Double Junction Re

Strona 13 - ISA=1 mL

6VIIVIIVIIVIIVII. General GuidelinesGeneral GuidelinesGeneral GuidelinesGeneral GuidelinesGeneral Guidelines• Use of a hood and protective clothing

Strona 14

7• Gas bubbles may form from solution out-gassing dueto temperature change. Gently tap body of sensor todislodge them from sensing membrane.HI 4

Strona 15

8VIII. VIII. VIII. VIII. VIII. Electrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationHI 4

Strona 16 - MAN4112 01/07

96. Holding the body of the electrode gently press uppercap with your thumb. This permits the fill solution todrain out of the body. Release cap and

Powiązane modele: HI 4112

Komentarze do niniejszej Instrukcji

Brak uwag